A007 ETL (schematic)
Overview
Below you will find the schematic A007 ETL as well as key operational features and additional support information to assist with your installation.

Installation Schematic A007 ETL
- The emergency door Buzzer circuit can be utilized to transmit the deactivation signal from RVT button to the module. The red wire on the RVT should be connected in this configuration to stop feedback onto the door buzzers.
- If there is no Buzzer circuit please use a direct connection from the RVT blue wire to the EP1plus blue wire
- The brown activation wire is typically connected to the red overhead lights or another 12V source (eg. brakes).
Operation Features
- Activates by the 8-way overhead red lights (or another 12V source)
- Deactivates in Key OFF position
- Horn will sound for 5 minutes if the child check is not completed
- The door is monitored and must remain closed during deactivation
- 4 minutes to perform the child check
- Can wait in Accessory position for up to 4 minutes (can be extended by cycling the key)
Order Information
Module: A007 ETL
Upgraded Component Kit: AC31 (For dome light, accessory and pilot light feature, LED not supplied)
- A033: RVT - Deactivation Button
- P100: 6-Pin Wire Harness
- A026: 3-Pin Diode Wire Harness
- P038: 2-Pin Wire Harness