A007 ETK (schematic)
Overview
Below you will find the schematic for A007 ETK as well as key operational features and additional support information to assist with your installation.

Installation Schematic A007 ETK
- The emergency door Buzzer circuit can be utilized to transmit the deactivation signal from RVT button to the module. The red wire on the RVT should be connected in this configuration to stop feedback onto the door buzzers.
- If there is no Buzzer circuit please use a direct connection from the RVT blue wire to the EP1plus blue wire
- The brown activation wire is typically connected to the red overhead lights or another 12V source (eg. brakes).
Operation Features
- Activation occurs after the ignition has been on for 4 seconds
- Deactivation in Key ON position
- 1 minute to perform the child check
- Horn will sound for 10 minutes if the child check is not completed
Order Information
Module: A007: ETK
Upgraded Component Kit: AC31 (For dome light, accessory and pilot light feature, LED not supplied)
- A033: RVT - Deactivation Button
- P100: 6-Pin Wire Harness
- A026: 3-Pin Diode Wire Harness
- P038: 2-Pin Wire Harness