Default System - A007 EPA (schematic)

Overview

The EP1plus Default System is our most cost-effective solution to help ensure no student is left unattended on a vehicle. Below you will find the schematic as well as key operational features and additional support information to assist with your installation.

Bus Installation Schematic

  • The emergency door Buzzer circuit can be utilized to transmit the deactivation signal from RVT button to the module. The red wire on the RVT should be connected in this configuration to stop feedback onto the door buzzers.
  • If there is no Buzzer circuit please use a direct connection from the RVT blue wire to the EP1plus blue wire
  • The brown activation wire is typically connected to the red overhead lights or another 12V source (eg. brakes).      
Operation Features 
  • Activation by the 8-way overhead red lights (or another 12V source)
  • Deactivates in Key ON position 
  • Unlimited time to perform the child check
  • Horn will sound for 5 minutes if the Child-Check is not completed
  • To silence the alarm, cycle the key off and then back to on
  • Dome lights will illuminate for 2 minutes after deactivation 
  • Can wait in Accessory position for up to 2 minutes (can be extended by cycling the key)
Order Information

Module & Instructional Decal: A007 EPA

Component Kit: AC01

  • P100: 6-pin wire Harness
  • A033: RVT Deactivation Button

Flex Component Kit: AC31 (For dome light, accessory and pilot light feature, LED not supplied)

  • A033: RVT - Deactivation Button
  • P100: 6-Pin Wire Harness
  • A026: 3-Pin Diode Wire Harness
  • P038: 2-Pin Wire Harness
Additional Support Information


How did we do?